menu
search product Keywords Only search title
Product ID: HVP-275
Inquire now or Add to Cart HVP-275 Side View
HVP-275 Side View
HVP-275 Bottom View

Inquire now or Add to Cart

High voltage proximity detector. ( HVP-275)

HVP-275 Features

• Sealed by " O" Ring.
• 8 voltage settings: 240Vac, 2kV, 6kV, 11kV, 22kV, 33kV,
132kV, and 275kV
• High bright LEDs visual indication
• Sound indication
• Easy-to-proov method
• Self-test selection
• Use 3 x 1.5V ??C?? batteries
• High impact nylon casing
• Non-contact work by proximity
• Compatible with most link sticks
• Light weight, robust, & compact
• Suitable for indoor and outdoor use
• Detect low voltage on any systems
• Easy access to batteries
• No special parts needed
• Three-year warranty
• Simple and efficient to use




Specifications:

  • Introduction:
    • The TECPEL HVP-275 is a high voltage proximity detector.
    • It has eight voltage detection settings from 240Vac to
    • 275kVac. The HVP-275 consists of an internal pickup
    • sensor plate, a sensitivity selector, a visual and a
    • sound annunciator. With the HVP-275, physical contact
    • with electrical conductors is not necessary when
    • testing for live lines. This tester works by proximity.
    • Its sensor senses the radiated field which surrounds
    • live conductors. Radiated field strength increases
    • with voltage and decreases quickly with distance or
    • earth shielding. The radiated field from a cable of
    • closely bunched conductors supplied by three phase
    • power tends to cancel (See ??Limitations of use??
    • paragraph). Detecting distance of a 250Vac single
    • live wire is approximately 10cm. With a bunched
    • neutral and earth cable, as in a flexible cable, the
    • distance is reduced to 5cm.
    • Some of the typical uses are : identify and check live
    • cables; find fault in flexible cables; check earth
    • equipment; service neon lightning; trace live wires;
    • check high frequency radiation; detect residual or
    • induced voltages. For example, faults in damaged
    • flexible cables are found by applying low voltage to
    • each conductor. Earthing the remainder and moving
    • the tester along the cable until the change in condition
    • is obtained. (Flexible cables which are used in mining
    • and building industries, are readily repairable when
    • the break in the cable is located.)
    • When testing for high voltage, the rotary switch
    • (attenuator) is used to identify and differentiate
    • various HV live cables. The tester must be used in
    • conjunction with a long and insulating rod when
    • measuring high voltage (kV). However, the HVP-275 is
    • a non-contact tester and it is advised that the tester
    • should never come into contact with cables (kV) as
    • this tester is merely a non-contact AC proximity tester.
    • Checking or proofing the tester is easy. Switch the
    • sensitivity to 240V and place the dome against a low
    • voltage live conductor or rub the dome with a cloth or
    • against an item of clothing as this generates a static
    • DC which triggers the detection of circuit. The light
    • and beeper should go ??on?? as if a live wire is being approached. Approaching the dome near a computer screen or a TV screen should also trigger
    • the tester while on the 240V selection. The power consumption of the 275HP is very low, and the
    • tester should always be tested as described above before using it.
  • Specifications:
    • Expected test results ( laboratory testing ) :
    • Range
    • 240V
    • 2kV
    • 6kV
    • 11kV
    • 22kV
    • 33kV
    • 132kV
    • 275kV
    • Typical observation of test results made in the field :
    • Range
    • 11kV
    • 22kV
    • 33kV
    • 132kV
    • 275kV
    • Operated from
    • Variable from 80V
    • or depending on the type of source
    • 250V
    • 500V
    • 1000V
    • 1500V
    • 4000V
    • 8000V
    • 22kV
    • Min. Detection MDV as % of
    • Voltage (MDV) Line Voltage
    • 1kV 9.1%
    • 2kV 9.1%
    • 3.1kV 9.4%
    • 12.5kV 9.5%
    • 22.5kV 8.2%
  • Limitation of usage.
    • It is recommended that the 275HP is not used in HV yards of mixed voltages.
    • In the presence of mixed voltages, the tester can become unreliable.
    • Problems can arise when the tertiary circuit of a 275/133/11kV transformer is
    • tested. The electric field of the HV and MV bus bars can trigger the detector when
    • it is about 3m above the ground. This is common with most of the electric field
    • voltage detectors, and the users should be aware of it. The tester can pick up
    • adjacent circuit to the one being tested and indicate the wrong information to the
    • user. Limitations of use :
    • It is recommended that the 275HP is not used in HV yards of mixed voltages.
    • In the presence of mixed voltages, the tester can become unreliable.
    • Problems can arise when the tertiary circuit of a 275/133/11kV transformer is
    • tested. The electric field of the HV and MV bus bars can trigger the detector when
    • it is about 3m above the ground. This is common with most of the electric field
    • voltage detectors, and the users should be aware of it. The tester can pick up
    • adjacent circuit to the one being tested and indicate the wrong information to the
    • user.


Contact Detail

Address:4F-1, No. 225, Sec. 3, He-Ping East Road Taipei, 110 Taiwan
TEL:886-2-27375866
FAX:886-2-27373343
Email:sales@tecpel.com ; tecpel@seed.net.tw
URL:http://www.tecpel.com http://www.oka.com.tw