Product ID: GOS - 6112 / 6103 / 6103C
100MHz Oscilloscope ( GOS - 6112 / 6103 / 6103C)
Cursor readout analog oscilloscope.
Specifications:
- CRT
- Type: 6-inch rectangular type with internal graticule; 0%, 10%, 90% and 100% markers. 8 x 10 DIV (1 DIV = 1cm).
- Phosphor: P31.
- Accelerating potential: 16 kV approx. (GOS-6103 / GOS-6103C), 12kV approx. (GOS-6112).
- Illumination: Continuously adjustable (GOS-6103/GOS-6103C).
- Z-axis input
- Coupling: DC.
- Sensitivity: 5V or more.
- Maximum input voltage: 30V (DC + AC peak) at 1kHz or less.
- Bandwidth: DC ~ 5MHz.
- Vertical system
- Sensitivity: 2mV ~ 5V / DIV, 11 step in 1-2-5 sequence.
- Sensitivity accuracy: < 3% (5 DIV at the center of display).
- Vernier vertical aensitivity: Continuously variable to 1 / 2.5 or less panel-indicate value.
- Bandwidth (-3dB): DC ~ 100MHz (2mV / DIV: DC ~ 20MHz).
- Rise time: 3.5nS (2mV / DIV: 17.5 nS).
- Signal delay: Leading edge can be monitored.
- Max. input voltage: 400V (DC + AC peak) at 1kHz or less.
- Input coupling: AC, DC, GND.
- Input impedance: 1M Ohm +2%// approx. 25pF.
- Vertical mode: CH1, CH2, DUAL (CHOP / ALT), ADD, CH2 INV.
- Bandwidth limited: 20MHz.
- Common-mode rejection ratio: 50 : 1 or better at 50kHz.
- Dynamic range
- 8 div at 60MHz; 5 div at 100MHz (GOS-6112).
- 8 div at 100MHz (GOS-6103 / GOS-6103C).
- Horizontal system
- Horizontal modes: MAIN (A), ALT, DELAY (B).
- A (main) sweep time: 50nS ~ 0.5S / DIV, continuously variable (UNCAL).
- B (delay) sweep time: 50nS ~ 50mS / DIV.
- Accuracy: +3% (+5% at x 10 MAG).
- Sweep magnification: x 10 (maximum sweep time 5nS / DIV).
- Hold off time: Variable.
- Delay time: 1 micro sign S ~ 5S.
- Delay jitter: Better than 1:20000.
- Alternate separation: variable.
- Trigger
- Trigger modes: AUTO, NORM, TV.
- Trigger source: CH1, CH2, LINE, EXT.
- Trigger coupling: AC, DC, HFR, LFR.
- Trigger slope: '+' or '-' polarity or TV sync polarity.
- Trigger sensitivity:
- AUTO
- Frequency: 10Hz~20MHz.
- INT: 0.35 DIV.
- EXT: 50 mV.
- AUTO
- Frequency: 20MHz~100MHz.
- INT: 1.5 DIV 50 mV.
- EXT: 150 mV.
- NORM
- Frequency: DC~20MHz.
- INT: 0.35 DIV.
- EXT: 50 mV.
- NORM
- Frequency: 20MHz~100MHz.
- INT: 1.5 DIV.
- EXT: 150 mV.
- TV
- Frequency: 20MHz~100MHz.
- INT: 1 DIV.
- EXT: 200 mV pp.
- TV Sync: TV-V, TV-H
- Max. external input voltage: 400V (DC + AC peak) at 1kHz.
- External input impedance: 1M Ohm + 5%, // approx. 25pF
- X-Y operation
- Mode
- X-axis: selectable CH1, CH2, EXT.
- Y-axis: selectable CH1, CH2, CH1 and CH2.
- Sensitivity accuracy: 2mV ~ 5V / DIV + 3%; EXT: 0.1V / DIV + 5%.
- X-axis bandwidth: DC ~ 500kHz (-3dB).
- Phase error: 3 degrees or less from DC ~ 50kHz.
- Output signal
- Trigger signal output
- Voltage: approx. 25mV / DIV into 50 Ohm.
- Frequency response: DC ~ 10MHz.
- Calibrator output: 1kHz squarewave, 2Vpp + 2%.
- Cursor readout function
- Cursor measurement function: V, V%, VdB, T, 1 / T, T%, Dia.
- Cursor resolution: 1 / 100 DIV.
- Effective cursor range: vertical: + 3DIV; horizontal: + 4DIV.
- Panel setting display:
- Vertical: V / DIV (CH1, CH2), UNCAL, ALT / CHOP / ADD, INV, probe factor, AC / DC / GND.
- Horizontal: S / DIV (MTB, DTB), UNCAL, x 10MAG, delay time, HO.
- Trigger: Source, coupling, slope, level, TV-V, TV-H.
- Others: X-Y, lock, save / recall MEM 0-9 (GOS-6103 / GOS-6103C).
- Auto measurement function (GOS-6103C)
- Parameter function: FREQ, PERIOD, +WIDTH, +DUTY (+ or - polarity selected by trigger slope).
- Display digits: Max. 6-digits, decimal.
- Frequency range: 50Hz ~ 100MHz.
- Accuracy: 1kHz ~ 100MHz: +0.01%; 50Hz ~ 1kHz: +0.05%.
- Measuring sensitivity: > 2 div (measuring source selected from CH1 and CH2 as synchronous signal sources).
- Special function
- Time / DIV auto range: Provided (GOS-6103 / GOS-6103C).
- Panel setting save & recall: 10 sets (GOS-6103 / GOS-6103C).
- Panel setups lock: Provided.
- Power source: AC 100V / 120V / 230V + 10%, 50 / 60Hz.
- Accessories
- Power cord x 1.
- Instruction manual x 1.
- Probes (10:1 / 1:1) x 2.
- Dimensions & weight: 310 (W) x 150 (H) x 455 (D) mm; approx. 9kg.
Features:
- 100 MHz, dual channel, delayed sweep.
- Built-in 6 digit universal counter (GOS-6103C).
- 10 sets memory for front panel setting save & recall (GOS-6103 / GOS-6103C).
- Time base auto-range (GOS-6103 / GOS-6103C).
- Cursor readout with 7 measurements.
- Panel setup lock of digital-control functions.
- Buzzer alarm.
- LED indicators.
- TV synchronization.
- Trigger signal output.
- Z-axis modulation input.
- SMD technology, high stability and reliability.
Copyright © 2009 Tecpel Co., Ltd. All rights reserved.