Measurement rate: Approx. 1 time per second, nominal.
General
Power requirement:
Single standard 9V battery (NEDA 1604, IEC 6F22 006P).
External DC adapter 12Vmim to 15Vmax / 50mA. (optional).
Auto power off: The meter key switch inactive for more than 5 minutes, press power key to resume operation.
Overload protection: 0.1A / 250V fast below fuse.
Ambient operating ranges: 0 deg C to 50 deg C (-32 deg F to 122 deg F) < 80% R.H.
Storage temperature: -20 deg C to 60 deg C (-4 deg F to 140 deg F) < 70 % R.H.
Dimensions: 192mm (H) x 91mm (W) x 52.5mm (D).
Weight: 365g. (including accessories).
Accessories: Comes complete with leads, battery and owners manual.
Features:
Basic accuracy: 0.5% for resistance; 0.7% for inductance, capacitance.
Dual displays provide quick tested results readouts, with L.C.R. display values up to 19999 counts and Q.D.R. display values up to 9999 counts (auto range).
Excellent resolutions: Resistance up to 0.001W, inductance capacitance up to 0.1uH / 0.1pF.
Provided up to 4 testing parameters: Ls + (Q, D, Rs), Lp + (Q, D, Rp); Cs + (Q, D, Rs), Cp + (Q, D, Rp).
Auto-power off function: To conserve battery life for longer use.
Fuse detection function: To inform that the fuse is open or damaged.
PC communication port: (Only for model LCR 612R) provide optical standard RS-232 cable.
External DC adapter functions: Use of a DC adapter can also serve to disable auto power off function.
The test lead TL-06 (option) is specially designed for measuring SMD (surface mount device) resistor, capacitor and inductor.