Product ID: FG 32
3MHz Function Generator + 60MHz Freq. Counter ( FG 32)
| Standard value |
Gate time |
INT |
EXT. HF |
EXT. LF |
|
| 0.2Hz |
10S |
- |
- |
0.200Hz |
| 0.5Hz |
2S |
0.500Hz |
- |
0.500Hz |
| 1Hz |
1S |
1.000Hz |
- |
1.000Hz |
| 10Hz |
0.25S |
10.000Hz |
- |
10.000Hz |
| 100Hz |
0.25S |
100.00Hz |
- |
100.00Hz |
| 1KHz |
0.25S |
1.000KHz |
- |
1.000KHz |
| 10KHz |
0.25S |
10.000KHz |
- |
10.000KHz |
| 100KHz |
0.25S |
100.0KHz |
100.00KHz |
100.0KHz |
| 1MHz |
0.25S |
1000.0KHz |
1000KHz |
- |
| 10MHz |
0.25S |
- |
10000KHz |
- |
| 60MHz |
0.25S |
- |
60000KHz |
- |
Specifications:
- Main output
- Frequency range: 0.5Hz ~ 3MHz in 6 ranges, 5 digits LED display, high resolution 0.001Hz, use rotary switch to select ranges.
- Waveform: 6 waveforms (sins, square, triangle, ramp, + pulse, - pulse), use rotary switch to select waveform.
- Stability: 0.1% after 15 minutes; 0.2% after 24 hours.
- DC offset: +/- 10V with pull adjust. Switch; +/- 10V (no load), +/- 5V (50 Ohm load).
- Ramp
- Frequency range: 0.5Hz ~ 2.5MHz, use 5 digits LED display.
- Max. resolution: 0.001Hz.
- Symmetry: 50% (rise waveform) to 50% (fall waveform) distortion < 1% (1Hz ~ 100KHz).
- Distortion: < 1% (1Hz ~ 100KHz).
- Triangle
- Frequency range: 0.5Hz ~ 3MHz, use 5 digits LED display.
- Max. resolution: 0.001Hz.
- Symmetry: 50% (rise waveform) to 50% (fall waveform) distortion < 1% (1Hz ~ 100KHz).
- Distortion: < 1% (1Hz ~ 100KHz).
- Sine ware
- Frequency range: 0.5Hz ~ 3MHz, use 5 digits LED display.
- Max. resolution: 0.001Hz.
- Symmetry: 50% (rise waveform) to 50% (fall waveform) distortion < 1% (1Hz ~ 100KHz).
- Distortion: < 1% to 100KHz.
- Harmonic ratio: < 30dB to 3MHz.
- Freq. response: < 0.1dB to 100 MHz < 1dB to 3MHz.
- Square
- Frequency range: 0.5Hz ~ 3MHz, use 5 digits LED display.
- Max. resolution: 0.001Hz.
- Symmetry: 50% (positive half circle) to 50% (negative half cycle) distortion < 1% to 100KHz.
- Rise time: < 60nS.
- + Pulse
- Freq. range: 0.5Hz ~ 3MHz, use 5 digits LED display.
- Max. resolution: 0.001Hz.
- + Pulse width: 0.4 sec ~ 100nS (continuously variable).
- Symmetry: 50% (positive half circle) to 50% (negative half cycle) distortion < 1% to 100KHz.
- Rise time: < 60nS.
- - Pulse
- Freq. range: 0.5Hz ~ 3MHz, use 5 digits LED display.
- Max resolution: 0.001Hz.
- - Pulse width: 0.4 sec ~ 100nS.
- Symmetry: 85% (+ time base) to 15% (- pulse) distortion < 5% to 100KHz.
- Fall time: < 60nS.
- Main output
- Output impedance: 50 Ohm, distortion < 2%.
- Max. output: 20Vp-p (no load), 0.05Vp-p (50 Ohm load) distortion: +/- 0.5V.
- Min. output: 0.1Vp-p (no load), 0.05Vp-p (50 Ohm load).
- Attenuator: -20dB attenuator; attenuation < 2%.
- Sync output
- Output impedance: 50 Ohm, distortion < 2%.
- Output level: TTL level > 3Vp-p fix amplitude.
- Rise time: < 40nS.
- VCF input
- Input level: 0 ~ 10V input.
- Max. freq. variable rate: 1 : 1 ~ 1 : 1000.
- Input frequency: DC ~ 1KHz.
- Sweep sync output
- Output impedance: 1K Ohm, distortion < 2%.
- Output waveform: Linearity or LOG sweep or LOG sweep slope.
- Output amplitude: 10Vp-p (load), 5Vp-p (51K Ohm load).
- Output frequency: Continuously variable, 0.2Hz ~ 100Hz.
- Sweep
- Sweep mode: Linear / log sweep, use switch selector.
- Sweep rate: 5 sec ~ 10mS, continuously variable.
- Sweep width: 1 : 1 ~ 1 : 100 (to cooperate with freq. knob).
- Frequency counter
- Display: 5 digits 0.36' red LED display.
- Max. resolution: 0.001Hz.
- Unit: Hz / KMz.
- Time base: 20MHz.
- Temp. characteristic: < 10PPM.
- Distortion: < 0.002%.
- Power source: + 5V / 160Ma.
- Internal counter
- Range: Auto range (0.001Hz / 0.01Hz / 0.001KHz / 0.01KHz), total 4 ranges, resolution, CPU select one to display.
- Counter range: 0.500Hz ~ 3000.0 KHz, auto select decimal point and display unit.
- Gate time: Variable 0.25 sec ~ 2 sec auto set.
- Minimum display: 4 digits.
- External counter
- Max. input voltage: < 250Vrms.
- Input impedance: 1M, distortion < 2%.
- Input frequency range: 0.2Hz ~ 60MHz.
- Attenuation switch: x 20 (-26nB).
- (Coupling)
- AC (HF) measure frequency over 100KHz through capacitor coupling.
- DC (LF) 100KHz filter - measure frequency under 100KHz direct coupling.
- (Gate time): Variable 0.25 sec ~ 10 sec auto set by frequency.
- Range: Auto range (0.001Hz / 0.01Hz / 0.001KHz / 0.1KHz / 1KHz) 5 kinds of resolution selected by CPU.
- Minimum display: 4 digits.
- Input sensitivity: < 30mVrms (1MHz).
- General specifications:
- Operating temp.: Temperature: 0 ~ 40 deg C; humidity 0 ~ 90% RH.
- Power source
- AC 115V (+/- 10%) 50 / 60Hz, fuse 600mA.
- AC 230V (+/- 10%) 50 / 60Hz, fuse 300mA.
- Consumption: Max 25VA (watt).
- Heat ventilation: Use fan DC 12V / 100mA.
- Safety approval: CE, GS, UL, CUL approval.
- Dimensions: 275mm (Width) x 90mm (Height) x 300mm (Depth).
- Weight: 2.5kg (net).
- Accessories: Operation manual, test leads, power cord.
Features:
- 6 function, 6 ranges.
- Frequency range 0.5Hz ~ 3MHz.
- Linear / log sweep function.
- Frequency counter 0.2 ~ 60MHz.
- Frequency counter max. resolution 0.001Hz.
- Calculation time table for frequency display value / gate time.
Copyright © 2009 Tecpel Co., Ltd. All rights reserved.